AKD Benutzerhandbuch | 24.12.6 DOUT1.STATE AND DOUT2.STATE

24.12.6 DOUT1.STATE AND DOUT2.STATE

General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Paramter
DOUT1.STATE
DOUT2.STATE
Fieldbus Index/Subindex
Modbus
Description
Reads the state of one digital output according to the value stated in the command.
AKD-C and AKD-N only support DOUT1.
Related Topics
Digitalausgänge (S. 118)
R/O Parameter
Reads the digital output
state.
N/A
0 to 1
N/A
Integer
Variant
Fieldbus
Address Attributes Signed?
Profinet
2101
sercos ® III
Profinet
2106
sercos ® III
202
DOUT1.STATE
212
DOUT2.STATE
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Byte
2 Octets
No
Byte
2 Octets
Is 64 bit? Attributes Signed? Object Start Version
No
8 bit
No
M_01-03-00-000