AKD Benutzerhandbuch | 24.27.7 MODBUS.SCALING

24.27.7 MODBUS.SCALING

General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Version M_01-04-15-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 1048
Description
Modbus has its own scaling algorithms. For some simple HMI's, it is desirable to use Workbench units
instead of these Modbus-specific units. The parameter MODBUS.SCALING allows users to disable Mod-
bus scaling and enable WB (Telnet) scaling.
Setting
Related Topics
UNIT Parameters (S. 1109)
884
KOLLMORGEN | Mai 2014
NV Parameter
Selects the scaling mode for Modbus
values.
N/A
0 to 1
1
U8
Variant
Address Attributes Signed?
Byte
2524
2 Octets
No
0
Modbus uses same scaling units as Workbench (set by UNIT parameters)
1
Modbus uses the Modbus-specific scaling units (set by MODBUS parameters)
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
8 bit
No
Description