Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

AKD Benutzerhandbuch | 24.24.9 IL.FBSOURCE

24.24.9 IL.FBSOURCE

General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Ver-
sion
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 1730
Description
This parameter selects the feedback source that current loop uses for commutation angle calculation. It
applies only when MOTOR.TYPE = 4.
0 = Primary feedback
1 = Secondary feedback
2 = Tertiary feedback
When IL.FBSOURCE is changed, MOTOR.POLES and MOTOR.PHASE are updated.
IL.FBSOURCE MOTOR.PHASE is set to: MOTOR.POLES is set to:
0
FB1.MOTORPHASE
1
FB2.MOTORPHASE
2
FB3.MOTORPHASE
For induction motor closed loop control the commutation angle is set as shown in the following figure.
R/W
Sets the feedback source for the current loop. Only applies when
MOTOR.TYPE = 4.
N/A
0 to 2
0
Integer
M_01-08-00-000
Variant
Supported
Address Attributes Signed?
Byte
2865
No
2 Octets
No
FB1.MOTORPOLES
FB2.MOTORPOLES
FB3.MOTORPOLES
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
8-bit
No
KOLLMORGEN | Mai 2014
827

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Akd-c01007-cbecAkd

Inhaltsverzeichnis