AKD Benutzerhandbuch | 24.22.8 HOME.MAXDIST
Description
HOME.MAXDIST sets the maximum distance the motor is allowed to move during the homing routine. If
the motor moves this distance before reaching the homing trigger, then the drive generates warning 174
and the motor decelerates to a stop at a rate of HOME.DEC (S. 793).
Related Topics
Referenzfahrt (S. 162)