AKD Benutzerhandbuch | 24.24.29 IL.MFOLDR
24.24.29 IL.MFOLDR
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 466
Description
IL.MFOLDR sets the recovery time for the motor foldback algorithm. If 0 current is applied for at least the
recovery time duration, it is possible to apply motor peak current for the duration of IL.MFOLDD time.
The IL.MFOLDR value is automatically calculated from other foldback parameters.
Related Topics
Stromregelkreis (S. 149)
850
KOLLMORGEN | Mai 2014
R/O Parameter
Sets the motor foldback recovery time.
s
0.1 to 65,535 s
Calculated from other foldback param-
eters.
Float
Foldback
Variant
Supported
Address Attributes Signed?
DWord
2233
No
4 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
32 bit
No
M_01-03-00-000