AKD Benutzerhandbuch | 24.28.1 MOTOR.AUTOSET
24.28.1 MOTOR.AUTOSET
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 480
Description
This parameter determines whether or not certain drive parameters (see lists below) are calculated auto-
matically. When MOTOR.AUTOSET = 1 these parameters are automatically calculated from the motor
ID data (read from memory-supporting feedback devices). Parameters loaded from motor memory are
then read-only and cannot be modified as long as MOTOR.AUTOSET = 1. If MOTOR.AUTOSET = 0,
parameters are not loaded from motor memory and must be configured by the user. Parameters which are
not loaded from motor memory are always read-write.
NV Parameter
Determines which drive parameters are calculated auto-
matically.
N/A
0 to 1
0
Boolean
N/A
Variant
Supported
Index/Subindex Object Start Version
3451h/0
Address Attributes Signed?
Byte
2240
No
2 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
M_01-00-00-000
8 bit
No
M_01-03-00-000