AKD Benutzerhandbuch | 24.28.1 MOTOR.AUTOSET
Three conditions determine which parameters are calculated automatically by MOTOR.AUTOSET = 1.
See the lists below to determine which parameters will automatically be configured from the motor ID
data.
The following parameters may be configured automatically when MOTOR.AUTOSET = 1:
MOTOR.BRAKE (S. 889)
l
MOTOR.CTF0 (S. 895)
l
MOTOR.ICONT (S. 897)
l
MOTOR.INERTIA (S. 904)
l
MOTOR.IPEAK (S. 905)
l
MOTOR.KE (S. 906)
l
MOTOR.KT (S. 908)
l
MOTOR.LQLL (S. 912)
l
MOTOR.NAME (S. 913)
l
MOTOR.POLES (S. 918)
l
MOTOR.R (S. 920)
l
If the motor's FB1.MEMVER > 0.01, AKD will also configure:
MOTOR.PHASE (S. 914)
l
MOTOR.TBRAKEAPP (S. 924)
l
MOTOR.PHASE (S. 914)
l
MOTOR.VRATED (S. 941)
l
MOTOR.VOLTRATED (S. 939)
l
For firmware versions 01-09-00-000 and later, AKD will also configure:
MOTOR.RTYPE (S. 921)
l
MOTOR.TEMPFAULT (S. 931)