AKD Benutzerhandbuch | 24.15.2 FAULT564.ACTION, FAULT565.ACTION
24.15.2 FAULT564.ACTION, FAULT565.ACTION
General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Version M_01-09-10-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 280
Description
These parameters set the action the AKD-C uses when the node count on string 1 (F564) or string 2
(F565) decreases. The supervision of nodes begins as soon as the nodes are powered (CPS.ACTIVE >=
3).
Value Action
0
Disable amplifier
1
Ignore
4
Generate warning
666
KOLLMORGEN | Mai 2014
R/W Parameter
Gets/Sets the fault action for either fault 564 or 565 in the AKD-
C.
N/A
0, 1, 4
4
Integer
Variant
Supported
Address Attributes Signed?
Byte
2140
No
2 Octets
No
No
No
No
No
No
No
No
No
No
No
Yes
8 bit
No
M_01-03-00-000