Herunterladen Inhalt Inhalt Diese Seite drucken

Kollmorgen AKD-C01007-MCEC Benutzerhandbuch Seite 1045

Inhaltsverzeichnis

Werbung

AKD Benutzerhandbuch | 24.33.14 REC.TRIG
24.33.14 REC.TRIG
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Description
REC.TRIG starts the trigger according to the trigger type defined by REC.TRIGTYPE.
REC.TRIG sets the value of REC.DONE to 0.
After calling REC.TRIG, the data that was recorded by previous recording is deleted and cannot be
retrieved.
No REC parameters can be set after a call to REC.TRIG until the recorder has finished or until REC.OFF
is executed.
Related Topics
 Oszilloskop (S. 250)
Command
Triggers the recorder.
N/A
N/A
N/A
N/A
REC.RETRIEVE,
REC.OFF
Variant
Supported
Address Attributes Signed?
2360
Command No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes