Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

AKD Benutzerhandbuch | 24.24.28 IL.MFOLDD

24.24.28 IL.MFOLDD

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 464
Description
IL.MFOLDD sets the maximum time allowed for the motor to remain at peak current before starting to fold
towards the motor continuous current. When at motor peak current, IL.MFOLDD is the amount of time
before the foldback algorithm starts to reduce the current.
Related Topics
 Stromregelkreis (S. 149)
R/O Parameter
Sets the motor foldback maximum time at motor peak cur-
rent.
s
0.1 to 2400 s
10 s
Float
Foldback
Variant
Supported
Address Attributes Signed?
DWord
2232
No
4 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
32 bit
No
M_01-03-00-000
KOLLMORGEN | Mai 2014
849

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Akd-c01007-cbecAkd

Inhaltsverzeichnis