Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

AKD Benutzerhandbuch | 24.28.38 MOTOR.VOLTMIN

24.28.38 MOTOR.VOLTMIN

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1674
Description
This parameter configures the drive for the induction motor's minimum voltage at standstill. It is given as a
percentage (%) of the motor's rated voltage. MOTOR.VOLTMIN is used to calculate the constant volts
per Hertz characteristics of the drive and motor and should be set to a value that generates a current of
about 40% of the rated current at standstill.
Related Topics
8.1
Motor
938
KOLLMORGEN | Mai 2014
NV Parameter
Sets the minimum voltage for V/f control.
%
0 to 100%
2%
U16
MOTOR.VRATED (S. 941), MOTOR.VOLTRATED (S.
939)
Variant
Supported
Index/Subindex Object Start Version
3457h/3
Address Attributes Signed?
Word
2837
No
2 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
M_01-00-00-000
16-bit
No
M_01-06-03-000

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Akd-c01007-cbecAkd

Inhaltsverzeichnis