AKD Benutzerhandbuch | 24.45.5 VBUS.UVFTHRESH
24.45.5 VBUS.UVFTHRESH
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 800
Description
VBUS.UVFTHRESH sets the undervoltage fault level of the DC bus.
The default value is read from the EEPROM, but can by modified by the user and stored on the NV RAM.
This value varies according to drive type.
Related Topics
Brems-Chopper (S. 65)
R/W Parameter
Sets the under voltage fault
level.
VDC
90 to 420 VDC
90 VDC
Integer
VBUS.OVFTHRESH
Variant
Supported
Address Attributes Signed?
Word
2400
No
2 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
16 bit
No
M_01-03-00-000