AKD Benutzerhandbuch | 24.34.6 REGEN.WATTEXT
24.34.6 REGEN.WATTEXT
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 744
Description
Sets the regen resistor's power fault level for an external regen resistor (when REGEN.TYPE = -1).
Above this fault level, the regen resistor's PWM wil be 0 and a fault will be issued.
Related Topics
7.2 Brems-Chopper
1063
KOLLMORGEN | Mai 2014
R/W parameter
Sets the regen resistor's power fault level for an external regen
resistor.
W
0 to 62,000 W
1000 W
Integer
N/A
Variant
Supported
Index/Subindex Object Start Version
3414h/0
Address Attributes Signed?
Word
2372
No