AKD Benutzerhandbuch | 24.34.2 REGEN.POWERFILTERED
24.34.2 REGEN.POWERFILTERED
General Information
Type
Description Returns a filtered version of REGEN.POWER .
Units
Range
Default
Value
Data Type
Start Ver-
sion
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 1736
Description
This parameter returns a filtered value of REGEN.POWER. A single order lowpass of 1/REGEN.TEXT
Hz is applied to generate REGEN.POWERFILTERED.
If REGEN.POWERFILTERED exceeds the value of REGEN.WATTEXT, Fault 521 (Regen overpower)
will be generated.
This keyword may be recorded in the scope screen for analysis.
Example
REGEN.TEXT = 10 (seconds)
Lowpass Filter Frequence = 1/10 seconds = 0.1 Hz
REGEN.POWERFILTERED = REGEN.POWER * 0.1Hz lowpass
Related Topics
R/O parameter
Watt
0 to REGEN.WATTEXT
0
Integer
M_01-07-01-000
Variant
Supported
Address Attributes Signed?
DWord
2868
No
8 Octets
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
64-bit
No