AKD Benutzerhandbuch | 24.47.3 WS.CHECKT
24.47.3 WS.CHECKT
General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Ver-
sion
Variants Supported
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 1700
Description
This parameter sets the amount of time a communication error must be present before an error is thrown.
Commutation monitoring is disabled when this parameter is set to 0.
Related Topics
Wake&Shake Übersicht (S. 78) | WS.CHECKV (S. 1186)
R/W Parameter
Sets the amount of time a communication error must be present before an error
is thrown.
ms
0 to 10,000
N/A
U16
M_01-06-03-000
Variant
Supported
Address Attributes Signed?
Word
2850
No
2 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
16-bit
No
KOLLMORGEN | Mai 2014