AKD Benutzerhandbuch | 25.12.7 DOUT1.STATEU AND DOUT2.STATEU

25.12.7 DOUT1.STATEU AND DOUT2.STATEU

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-01-01-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex
Modbus
Description
DOUT1.STATEU and DOUT2.STATEU set the state of the digital output node as follows:
0 = deactivated
1 = activated
DOUT1.STATEU and DOUT2.STATEU are used when DOUT1.MODE to DOUT19.MODE (s: 501) = 0
(user mode).
Related Topics
Digitalausgänge (s: 107)
506
KOLLMORGEN | Mai 2013
R/W Parameter
Sets the state of the digital output
node.
N/A
0 to 1
0
Integer
N/A
Variant
204
DOUT1.STATEU
214
DOUT2.STATEU
DOUT1.STATEU
DOUT2.STATEU
Supported
Supported
N/A
Is 64 bit? Attributes Signed? Object Start Version
No
8 bit
No
M_01-03-00-000