Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.17.5 FB2.POFFSET

25.17.5 FB2.POFFSET

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-05-11-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1638
Description
FB2.POFFSET is the value added to the primary feedback position (FB2.P (s: 638)).
Example
If FB2.P is 10000 counts and FB2.POFFSET is set to –10000 counts, then the next read of FB2.P will
return ~0 counts.
640
KOLLMORGEN | Mai 2013
NV-Parameter
Sets the offset for secondary feedback.
counts, custom units
-5,123,372,000,000,005.000 to 5,123,372,000,000,005.000 counts
or
-10,485,760.000 to 10,485,760.000 custom units
0
S64
N/A
Variant
Supported
Yes
64-bits
N/A
N/A
Yes
M_01-06-03-000