AKD Benutzerhandbuch | 25.24.25 IL.LIMITP
25.24.25 IL.LIMITP
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 462
Description
This parameter sets the positive user limit clamp value of the torque-producing q-component current com-
mand (IL.CMD (s: 713)). The current command is additionally limited by the motor peak current setting
(MOTOR.IPEAK (s: 784)) and by the present value of the foldback I²t peak motor current protection.
Related Topics
13.3 Stromregelkreis
NV Parameter
Sets the positive user (application-specific) current
limit.
A
0 A to drive peak current (DRV.IPEAK)
Drive peak current (DRV.IPEAK)
Float
IL.LIMITN (s: 735)
Variant
Supported
Index/Subindex Object Start Version
356Eh/0
No
32 bit
√
√
√
M_01-00-00-000
Yes
M_01-03-00-000
KOLLMORGEN | Mai 2013
736