AKD Benutzerhandbuch | 25.16.21 FB1.POFFSET

25.16.21 FB1.POFFSET

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-05-11-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1618
Description
FB1.POFFSET is the value added to the primary feedback position (FB1.P (s: 615)).
Example
If FB1.P is 10000 counts and FB1.POFFSET is set to –10000 counts, then the next read of FB1.P will
return ~0 counts.
NV-Parameter
Sets the offset for primary feedback.
counts, custom units
-5,123,372,000,000,005.000 to 5,123,372,000,000,005.000 counts
or
-10,485,760.000 to 10,485,760.000 custom units
0
S64
N/A
Variant
Supported
Yes
64-bits
N/A
Yes
M_01-06-03-000
KOLLMORGEN | Mai 2013