AKD Benutzerhandbuch | 25.24.27 IL.MFOLDR
25.24.27 IL.MFOLDR
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 466
Description
IL.MFOLDR sets the recovery time for the motor foldback algorithm. If 0 current is applied for at least the
recovery time duration, it is possible to apply motor peak current for the duration of IL.MFOLDD time.
The IL.MFOLDR value is automatically calculated from other foldback parameters.
Related Topics
Stromregelkreis (s: 138)
R/O Parameter
Sets the motor foldback recovery time.
s
0.1 to 65,535 s
Calculated from other foldback param-
eters.
Float
Foldback
Variant
Supported
No
32 bit
√
√
√
No
M_01-03-00-000
KOLLMORGEN | Mai 2013
738