AKD Benutzerhandbuch | 25.15.1 FAULTx.ACTION
25.15.1 FAULTx.ACTION
General Information
Type
Description
Units
Range
Default
Value
Data Type Integer
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex
Modbus
Description
This Parameter determines the action the drive should take when Fault 130, 131, 132, 134, 139, 451, or
702 occurs.
Parameter Value
0
1
596
KOLLMORGEN | Mai 2013
R/W
Gets/Sets the Fault Action for Fault 130, 131, 132,
134, 139, 451, and 702.
N/A
0 to 1
0
M_01-04-16-000
Variant
1202
FAULT130.ACTION
1204
FAULT131.ACTION
1206
FAULT132.ACTION
1208
FAULT134.ACTION
1594
FAULT139.ACTION
1210
FAULT702.ACTION
1230
FAULT451.ACTION
Drive Action
Disable Ampllifier
Ignore (fault will not be reported)
Supported
√
N/A
N/A
Is 64 bit? Attributes Signed?
No
8 bit
No