Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.20.3 GEAR.IN

25.20.3 GEAR.IN

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex
Modbus 374
Description
This parameter sets the denominator of the gear ratio for the electronic gearing mode. The gear ratio is
used in order to increase and decrease the slave velocity. The slave velocity can be calculated by the fol-
lowing formula:
Slave velocity = Master velocity * GEAR.OUT (s: 673)/GEAR.IN
Be sure that you set the external master source number of signals per revolution correctly. Also, select
the gear ratio so that the maximum electronic gearing velocity (GEAR.VMAX (s: 674)) is not exceeded.
Master velocitymax * GEAR.OUT (s: 673)/GEAR.IN < GEAR.VMAX (s: 674)
Related Topics
Elektronisches Getriebe (s: 119)
669
KOLLMORGEN | Mai 2013
NV Parameter
Sets the denominator of the electronic gearing ratio; active in opmode 2 (posi-
tion) only.
N/A
1 to 65,535
1
Integer
N/A
M_01-00-00-000
Variant
Supported
Is 64
Attributes Signed?
bit?
No
16 bit
N/A
Object Start Ver-
sion
No
M_01-03-00-000