Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.28.31 MOTOR.VOLTMIN

25.28.31 MOTOR.VOLTMIN

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1674
Description
This parameter configures the drive for the induction motor's minimum voltage at standstill. It is given as a
percentage (%) of the motor's rated voltage. MOTOR.VOLTMIN is used to calculate the constant volts
per Hertz characteristics of the drive and motor and should be set to a value that generates a current of
about 40% of the rated current at standstill.
Related Topics
8.1
Motor
NV Parameter
Sets the minimum voltage for V/f control.
%
0 to 100%
2%
U16
MOTOR.VRATED (s: 806), MOTOR.VOLTRATED (s:
805)
Variant
Supported
Index/Subindex Object Start Version
3457h/3
No
16-bit
N/A
N/A
M_01-00-00-000
No
M_01-06-03-000
KOLLMORGEN | Mai 2013
804

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis