AKD Benutzerhandbuch | 25.27.3 MODBUS.ERRORS

25.27.3 MODBUS.ERRORS

General Information
Type
Description
Units
Range
Default
Value
Data Type
Start Version M_01-08-03-001
Description
Lists up to 125 Modbus errors. Each entry contains the Modbus address and the error code of the failed
Modbus request.
If more than 125 errors occur, the oldest error is dropped and the new error is stored at the end of this list.
All modbus errors are stored regardless of the state of the error mode (MODBUS.ERRORMODE).
Access Through Telnet
Telnet or the WorkBench terminal will display the entire list:
Access Through Modbus
In Modbus the error list starts at register address 0x1102 (4354).
Modbus Address
4354
4355
4356
4357
4358
...
4603
4604
Related Topics
MODBUS.ERRORMODE (s: 763) | MODBUS.CLRERRORS (s: 762)
764
KOLLMORGEN | Mai 2013
R/O
Returns a list of up to 125 Modbus
errors.
N/A
N/A
N/A
N/A
-->MODBUS.ERRORS
Error count: 2
[00384]
6 : Argument lower than minimum.
[00390] 109 : Invalid Register address.
Description
Error count
Error 1 : Register Address
Error 1: Error Code
Error 2 : Register Address
Error 2 : Error Code
...
Error 125 : Register Address
Error 125 : Error Code