AKD Benutzerhandbuch | 25.41.12 VL.FBSOURCE

25.41.12 VL.FBSOURCE

General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 860
Description
This parameter determines the feedback source to be used by the velocity loop. A value of 0 selects the
primary feedback, and 1 selects the secondary feedback.
Related Topics
  Geschwindigkeitsregelkreis (s: 141)
967
KOLLMORGEN | Mai 2013
NV Parameter
Sets feedback source for the velocity loop; active in opmodes 1 (velocity) and 2
(position) only.
N/A
0 to 1
0
Integer
PL.FBSOURCE (s: 847)
M_01-00-00-000
Variant
Supported
No
8 bit
No
M_01-03-00-000