AKD Benutzerhandbuch | 25.28.26 MOTOR.TEMPFAULT
25.28.26 MOTOR.TEMPFAULT
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 516
Description
This parameter is used to configure the motor temperature fault level as a resistance threshold of the
motor thermal sensor.
A zero value prevents any fault from being issued.
For firmware versions 01-09-00-000 and later, this parameter is automatically configured
for KOLLMORGEN motors when MOTOR.AUTOSET = 1.
Related Topics
8.1
Motor
NV Parameter
Sets the motor temperature fault
level.
Ω
0 to 2,000,000,000 Ω
0 Ω = switched off
Integer
MOTOR.TEMP (s: 797)
Variant
Supported
Index/Subindex Object Start Version
3586h/0
No
32 bit
√
√
√
M_01-00-00-000
No
M_01-03-00-000
KOLLMORGEN | Mai 2013