Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.31.1 PLS.EN

25.31.1 PLS.EN

General Information
Type
Description Enables programmable limit switch (PLS).
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 618
Description
PLS.EN is a bit variable which determines the mode of an individual PLS. Eight PLSs are available in the
drive.
Example
Bit Value
Bit 0 = 0
Bit 0 = 1 Enables PLS 1
Bit 7 = 0
Bit 7 = 1 Enables PLS 8
Related Topics
  Programmierbarer Endschalter (s: 123)
861
KOLLMORGEN | Mai 2013
R/W Parameter
N/A
0 to 255
0
Integer
PLS.MODE (s: 862), PLS.RESET, PLS.STATE, PLS.UNITS, PLS.P1 to
PLS.P8, PLS.WIDTH1 to PLS.WIDTH8, PLS.T1 to PLS.T8
M_01-02-03-000
Variant
Index/Subindex Object Start Version
34A3h/1
No
Behavior
Disables PLS
1
Disables PLS
8
Supported
M_01-02-03-000
16 bit
No
M_01-03-00-000