AKD Benutzerhandbuch | 25.33.5 REGEN.TYPE

25.33.5 REGEN.TYPE

General Information
Type
Function
WorkBench Location (Screen/Dialog
Box)
Units
Range
Default Value
Data Type
See Also
Start Version
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 742
Description
You can specify a user-defined external regen resistor, select an internal regen resistor, or choose from a
list of predefined regen resistors. The values for REGEN.TYPE are shown below:
Type
External user-defined regen
–1
resistor
0
Internal regen resistor
If you specify a user-defined regen resistor, then you must also define this resistor's resistance
(REGEN.REXT), heatup time (REGEN.REXT), and power (REGEN.WATTEXT).
Related Topics
7.2 Brems-Chopper
Variant
Supported
Index/Subindex Object Start Version
3412h/0
No
8 bit
Description
NV Parameter
Sets the regen resistor type.
Power/Regen Resistor
Type
N/A
–1 to 0
0
Integer
N/A
M_01-00-00-000
M_01-00-00-000
Yes
M_01-03-00-000
KOLLMORGEN | Mai 2013