AKD Benutzerhandbuch | 25.28.25 MOTOR.TEMP
25.28.25 MOTOR.TEMP
General Information
Type
Description
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus
EtherCAT COE and CAN-
open
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 514
Description
This parameter returns the motor temperature, which is represented as the resistance of the motor's PTC
or NTC.
Related Topics
8.1
MotorMOTOR.RTYPE (s: 793)
797
KOLLMORGEN | Mai 2013
R/O Parameter
Reads the motor temperature represented as the resistance of the motor PTC
or NTC.
Ω
32
0 to 2
Ω
N/A
Integer
N/A
M_01-00-00-000
Variant
Supported
Index/Subindex Object Start Version
3612h/0
No
32 bit
√
√
√
M_01-00-00-000
No
M_01-03-00-000