AKD Benutzerhandbuch | 25.7.5 BODE.IFTHRESH
25.7.5 BODE.IFTHRESH
General Information
Type
Description Sets the current fault threshold for the BODE.MODE 5 stability test.
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1298
Description
When BODE.MODE (s: 441) is set to 5, the firmware monitors the drive current (IL.CMD (s: 713)). When
IL.CMD goes above BODE.IFTHRESH, an internal counter records the length of time IL.CMD was above
BODE.IFTHRESH. If the internal counter reaches BODE.IFLIMIT (s: 438), Fault 133 (Instability during
Autotune) is generated.
Example
Set BODE.IFTHRESH to 6 Amps:
-->BODE.IFTHRESH 6
Set BODE.IFLIMIT to 0.500 seconds:
-->BODE.IFLIMIT 0.5
Set BODE.MODE to 5 to enable stability detection:
BODE.MODE 5