AKD Benutzerhandbuch | 25.1.2 Summary of Parameters and Commands
Parameter or Command
PLS.RESET (➜ S. 1140)
PLS.STATE (➜ S. 1142)
PLS.T1 TO PLS.T8 (➜ S. 1144)
PLS.UNITS (➜ S. 1146)
PLS.WIDTH1 TO PLS.WIDTH8 (➜ S.
1149)
Recorder (REC)
REC.ACTIVE (➜ S. 1152)
REC.CH1 to REC.CH6 (➜ S. 1153)
REC.DONE (➜ S. 1154)
REC.GAP (➜ S. 1155)
REC.NUMPOINTS (➜ S. 1156)
REC.OFF (➜ S. 1157)
REC.RECPRMLIST (➜ S. 1158)
REC.RETRIEVE (➜ S. 1159)
REC.RETRIEVEDATA (➜ S. 1160)
REC.RETRIEVEFRMT (➜ S. 1162)
REC.RETRIEVEHDR (➜ S. 1164)
REC.RETRIEVESIZE (➜ S. 1165)
REC.STOPTYPE (➜ S. 1166)
REC.TRIG (➜ S. 1167)
REC.TRIGPARAM (➜ S. 1168)
REC.TRIGPOS (➜ S. 1169)
REC.TRIGPRMLIST (➜ S. 1171)
REC.TRIGSLOPE (➜ S. 1172)
REC.TRIGTYPE (➜ S. 1173)
REC.TRIGVAL (➜ S. 1175)
Regen Resistor (REGEN)
REGEN.POWER (➜ S. 1177)
REGEN.POWERFILTERED (➜ S.
1179)
REGEN.REXT (➜ S. 1181)
Type
Description
W/O
Resets programmable limit switch.
R/O
Reads the programmable limit switch state.
Sets programmable limit switch time .
R/W
Sets programmable limit switch (PLS) units.
R/W
Programmable Limit Switch Width
R/W
R/O
Indicates if data recording is in progress
(active).
R/W
Sets recording channels 1 to 6.
R/O
Checks whether or not the recorder has finis-
hed recording.
R/W
Specifies the gap between consecutive samp-
les.
R/W
Sets the number of points to record.
R/W
Turns the recorder OFF.
Reads the list of recordable parameters.
R/O
R/O
Transfers all the recorded data to the com-
munication channel.
Retrieves the recorded data without the hea-
R/W
der.
Sets the format for recorded data output.
R/W
Retrieves the recorded header without the
R/O
data.
Sets the number of samples that
R/W
REC.RETRIEVEDATA returns.
R/W
Sets the recorder stop type.
Command Triggers the recorder.
Sets the parameter that triggers the recorder.
R/W
R/W
Sets the trigger position in the recording buffer.
Reads the list of possible trigger parameters.
R/O
R/W
Sets the trigger slope.
R/W
Sets the trigger type.
R/W
Sets the trigger value.
R/O
Reads regen resistor's calculated power.
Returns a filtered version of REGEN.POWER
R/O
.
N/V
Sets the external, user-defined regen resistor
resistance.
KOLLMORGEN | Dezember 2014