Herunterladen Inhalt Inhalt Diese Seite drucken

Kollmorgen AKD-N-DB Benutzerhandbuch Seite 540

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.8.13 CMPx.WIDTH
Variant
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Description
Use this keyword to set the width for a Compare setpoint. The width defines for how much time or for
how many position counts a pulse will be generated once a setpoint is active.
If a pulse width's type is in microseconds, the resolution is as follows:
Width
0 to 65,535 μs
65,536 μs to 65.535 s ms
CMPx.WIDTH must be set before CMPx.SETPOINT (➜ S. 532).
Example
The following example sets the width type of setpoint 7 to microseconds, and the width of setpoint 7 to
1000 microseconds.
-->CMP0.WIDTHTYPE 7 1
-->CMP0.WIDTH 7 1000
Related Topics
Komparatoren (Vergleicher) (➜ S. 129)
CMPx.WIDTHTYPE (➜ S. 541)
540
KOLLMORGEN | Dezember 2014
Supported
Yes
Yes
Yes
Yes
Yes
No
No
Resolution
μs