AKD Benutzerhandbuch | 25.26.4 IP.RESET
IP.RESET will return an error if issued while the drive is enabled. IP.RESET is allowed when
l
drive is disabled, or in dynamic braking mode.
Ensure all values of IP.ADDRESS (➜ S. 955), IP.SUBNET (➜ S. 963), and IP.GATEWAY
l
(➜ S. 957) are configured if using IP.MODE 1
Recovering communications with a drive on an un-reachable IP address
Sometimes a drive may be configured for an IP Address, and the drive needs to be taken off-line, and
bench tested, or otherwise used outside of its saved IP Settings. If IP.MODE has been set to 1 (using
software defined static IP), the drive will boot up on an IP Address that may be unreachable with the
host computer's settings.
If the IP address prevents communication the IP settings can be reset to default by the following pro-
cedure:
Set both rotary switches to 0
l
Hold down button B1 (top-side of drive) for 5 seconds.
l
The display will flash 0.0.0.0 and then attempt to discover an address by DHCP. Without removing
logic power from the drive, use Workbench to connect to the drive, reconfigure the IP address settings
as desired, and store the values to non-volatile memory.
Related Topics
IP.ADDRESS (➜ S. 955) | IP.GATEWAY (➜ S. 957) | IP.SUBNET (➜ S. 963) | IP.MODE