General Information
Type
Description
Units
Range
Default Value Calculated from other foldback para-
Data Type
See Also
Start Version M_01-00-00-000
Variants Supported
Variant
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus
466
Description
IL.MFOLDR sets the recovery time for the motor foldback algorithm. If 0 current is applied for at least
the recovery time duration, it is possible to apply motor peak current for the duration of IL.MFOLDD
time.
The IL.MFOLDR value is automatically calculated from other foldback parameters.
Related Topics
Stromregelkreis (➜ S. 146)
942
KOLLMORGEN | Dezember 2014
R/O Parameter
Sets the motor foldback recovery time.
s
0.1 to 65,535 s
meters.
Float
Foldback