AKD Benutzerhandbuch | 25.7.1 CAP0.EDGE, CAP1.EDGE
25.7.1 CAP0.EDGE, CAP1.EDGE
General Information
Type
Description
Units
Range
Default Value 1
Data Type
Start Version M_01-00-00-000
Variants Supported
Variant
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Paramter
CAP0.EDGE Profinet
CAP1.EDGE Profinet
Fieldbus Index/Subindex
Modbus
54
80
Description
The filtered trigger source is monitored for rising edge, falling edge, or both edges. The event mode
logic may ignore the precondition edge detection; however, the trigger always uses edge detection.
488
KOLLMORGEN | Dezember 2014
NV Parameter
Selects the capture edge.
N/A
1 to 3
U8
Supported
Fieldbus
Address Attributes Signed?
2027
Byte
sercos ® III
2 Octets
2040
Byte
sercos ® III
2 Octets
Is 64 bit?
CAP0.EDGE
No
CAP1.EDGE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Attributes
8 bit
Object
Signed?
Start
Version
M_01-
No
03-00-
000