AKD Benutzerhandbuch | 25.14.35 DRV.HANDWHEEL
When secondary feedback is selected (DRV.EMUEMODE is 0 and FB2.SOURCE = 1 (X9), or
FB2.SOURCE = 2 (X7)), this parameter represents the secondary feedback position (where
4,294,967,296 is a full revolution, then the value rolls over). FB2.ENCRES defines how many counts
define a revolution for the secondary feedback.
Related Topics
DRV.EMUERES (➜ S. 656), DRV.EMUEMODE (➜ S. 649)
KOLLMORGEN | Dezember 2014