Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.25.9 IL.FBSOURCE

25.25.9 IL.FBSOURCE

General Information
Type
Description
Units
Range
Default Value 0
Data Type
Start Version M_01-08-00-000
Variants Supported
Variant
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Profinet
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus
1730
Description
This parameter selects the feedback source that current loop uses for commutation angle calculation.
It applies only when MOTOR.TYPE = 4.
0 = Primary feedback
1 = Secondary feedback
2 = Tertiary feedback
When IL.FBSOURCE is changed, MOTOR.POLES and MOTOR.PHASE are updated.
908
KOLLMORGEN | Dezember 2014
R/W
Sets the feedback source for the current loop. Only applies when MOTOR.TYPE = 4.
N/A
0 to 2
Integer
Supported
Address Attributes Signed?
2865
Byte
No
2 Octets
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
8-bit
No

Werbung