Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT F6 Programmierhandbuch Seite 525

Vorschau ausblenden Andere Handbücher für COMBIVERT F6:
Inhaltsverzeichnis

Werbung

Inverter-Parameter (Adresse / Auflösung / Typ)
vl: velocity mode
Sub-
Index
CAN
Type
IDtxt
Idx
2304h
0
V
UINT32
vl04
2305h
0
V
UINT32
vl05
2306h
0
V
UINT32
vl06
2307h
0
V
UINT32
vl07
2314h
0
V
INT32
vl20
2315h
0
V
INT32
vl21
2316h
0
V
INT32
vl22
2329h
0
V
INT32
vl41
232Ah
0
V
INT32
vl42
© 2021 KEB Automation KG
Name
Upper Limit
vl velocity min amount for
128000
vl velocity max amount for
128000
vl velocity min amount rev
128000
vl velocity max amount rev
128000
(CiA 0x6042) vl target velocity
128000
target velocity high res
1048576000
external target velocity
---
vl velocity actual limit for
---
vl velocity actual limit rev
---
Lower Limit
Default Value Mult.
Div
0
0
1
1
0
2000
1
1
0
0
1
1
0
2000
1
1
-128000
0
1
1
-1048576000
0
1
8192
---
---
1
8192
---
---
1
1
---
---
1
1
Unit
PD RO EOAD
1/min
---
---
1/min
---
---
1/min
---
---
1/min
---
---
1/min
X
---
1/min
X
---
9293,
1/min
X
X
9294
1/min
X
X
1/min
X
X
525

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Combivert s6

Inhaltsverzeichnis