Parameter
Setting
Soft water capacity
0 Litres
Cartridge replacement
18 months
Service menu
Parameter
Setting
Pressurisation
Compressor "ON"
P
+ 0.3 bar
0
Compressor "OFF"
P
+ 0.4 bar
0
"Compressor run time
240 minutes
exceeded" message
Comment
Replace cartridge.
Comment
Differential pressured added to
the "P
" minimum operating
0
pressure.
Differential pressured added to
the "P
" minimum operating
0
pressure.
The message is displayed after
the compressor runs for 240
minutes.
Reflexomat Silent Compact — 06.12.2023
Parameter
Setting
Overflow line "CLOSED"
P
+ 0.4 bar
0
Overflow line "OPEN"
P
+ 0.5 bar
0
Maximum pressure
P
+ 3 bar
0
Filling levels
Insufficient water "ON"
5 %
Insufficient water "OFF"
12 %
Solenoid valve in overflow
90 %
line "CLOSED"
Controller
Comment
Differential pressured added to
the "P
" minimum operating
0
pressure.
Differential pressured added to
the "P
" minimum operating
0
pressure.
Differential pressured added to
the "P
" minimum operating
0
pressure.
English — 33