General
Protection class according to
EN 60529/IEC 529
Ambient temperature
Electromagnetic compatibility
Interference immunity
Interference emission
Electrics
Logic operating voltage U
Operating voltage load
U
U
Q1
Q2
Cable length for power supply
Electrics
Inputs DIN EN 61131-2
Total current of 24 V sensor supply for all input modules limited to 0.7 A.
Input delay 0-1
Input delay 1-0
Line length for M8 and M12 connection
AVENTICS | DeviceNet | R499050019–BDL–001–AD
10 Technical Data
10.1 Characteristics
U
10.2 Bus coupler
L
Protective extra-low voltage (SELV/PELV) according to IEC 60364-4-41,
10.3 8x input modules, RMV04-8DI_M8 and
RMV04-8DI_M12
0 C to +50 C, without condensation
8 digital inputs, type 3, two-wire proximity switch with a
quiescent current of max. 2.5 mA can be connected
Technical Data
IP65 when assembled
EN 61131-2, EN 61000-6-2
EN 61000-6-4
24 V DC (+20 %/+15 %)
24 V DC (+10 %/–10 %)
Residual ripple 0.5 %
Max. 20 m
3 ms
3 ms
max. 30 m
127