O0...O7
4
3
1
1
2
5
4
3
AVENTICS | DeviceNet | R499050019–BDL–001–AD
Table 10:
Output assignment for 8x output module, DO8_M8,
M8x1 socket
Pin
Signal
1
Free
4
Ox
3
GND
Housing
Table 11:
Output assignment for 8x output module, DO8_M12,
M12x1 socket, A-coded
Pin
Signal
1
NC
2
O1, O3, O5 or O7
3
GND
4
O0, O2, O4 or O6
5
NC
Housing
Total current is too high
Every output is supplied with a continuous current of
max. 0.5 A. Current loads over 0.5 A per output can lead to
limited system functioning.
O
Make sure that the current load of 0.5 A per output is not
exceeded.
6.3.6
Connecting the output module load supply
Each output module has its own M12 connection for the load
supply. Each of the 4 outputs are supplied via the load supply.
The U
and U
voltages are galvanically isolated.
Q1
Q2
Assignment
Not connected
Ox output signal
(nominal voltage 24 V)
GND actuator reference
Connected to shield potential
Assignment
Not connected
Output signal
Reference potential
Output signal
Not connected
Connected to shield potential
NOTICE
103
Assembly