Herunterladen Inhalt Inhalt Diese Seite drucken

Kollmorgen AKD-N-DB Benutzerhandbuch Seite 1259

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AKD Benutzerhandbuch | 25.46.1 VBUS.HALFVOLT
Value Description
1
Setting the parameter to 1 on a HV Drive causes the AKD to use the voltage thresholds of an
MV drive for the functions mentioned below. Setting the parameter to 1 on a MV drive causes
the AKD to use the voltage thresholds of a LV drive for the functions mentioned below.
This parameter has an impact on the following voltage-thresholds:
1. DC-bus over-voltage threshold (see VBUS.OVFTHRESH (➜ S. 1260)).
2. The regen-resistor enable/disable voltage thresholds.
3. The inrush-relay enable/disable voltage thresholds.
The DC-bus under voltage fault threshold (see VBUS.UVFTHRESH (➜ S. 1263))
is a user selectable command. It means that the user is responsible for setting the
under voltage threshold to a proper value in case that the AKD is supplied with a
lower DC-bus voltage than the rated voltage.
KOLLMORGEN | Dezember 2014
1259

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Akd-n-dfAkd-n-ds

Inhaltsverzeichnis