Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB EcoAdd Betriebsanleitung Seite 394

Dynamische pumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Technical data
Electrical data
Description
Supply voltage [V / Hz]
Motor power [W]
Rated current [A]
Max. starting current [A]
Degree of protection
Protection class
Level, external release, batch
Inputs:
Pulse, standard signal (0/4-20 mA)
Minimum pulse duration (On/Off)
Alarm (relay contact)
Outputs:
Stroke signal (transistor)
External power supply
CAUTION!
When switching on the power supply, it must be ensured that no more than
two pumps are switched at one time, otherwise this may lead to a very high
start-up current (switching power supply).
Permissible cables:
Permissible external cable Ø for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34
Permissible cables: Oilflex 4x0.5
IP65 is applicable only when the specified cable is being used.
Equipment marking / nameplate
14
13
12
11
10
9
Fig. 108: Nameplate
1
QR code for maintenance
2
CE marking
3
Disposal regulations:
The product may not be disposed of in the household
waste!
4
Protection class Marking Type 2
5
Eurasian Conformity
6
Bar code with the annual production code
7
Manufacturer's address
8
Annual production code
MAN046939 Rev. 6-10.2021
16
17
8
6
7
Type
Type
00510X
01110S
100 - 240 ±10% / 50/60
30
0,13
Up to 45 (for 2 mSec.)
Max. 24 V DC / 6 mA
Max. 25 mA (approx. 50 Ohm)
Max. 24 V , DC, 200 mA
15
1
2
3
5
9
Material pairings of the pump
10 Power consumption
11
Voltage specification [V/Hz]
12 Q = Litre capacity [l/h]; p= Pressure [MPa]
13 Order number
14 Device type
15 Device designation
16 Barcode with order number
17 TÜV & UL Certification
190
Type
Type
Type
03003M
05010M
12003M
50
0,22
IP65
II
15 mS
230 V, AC/DC, 3 A
5 V, max. 100 mA
4

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis