Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB EcoAdd Betriebsanleitung Seite 388

Dynamische pumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Conversion, upgrade, repair
Change from stand mounting to wall mounting
To be able to adapt the pump to the local conditions, it is possible to use the pump
"upright" (stand mounting) or "suspended" (wall mounting).
3
Fig. 105: Change from stand mounting (upright, e.g. floor, bracket or canister) to wall mounting (hanging).
1.
Remove the connector lines as necessary (hydraulic and electrical).
2.
Press the fixing bracket on the mounting plate down to release the lock on the pump.
3.
Move the pump back on the mounting plate until the fastening elements from the
pump base engage into position.
4.
Remove the pump from the mounting plate by lifting upwards.
5.
Fit the mounting plate on the wall.
6.
Place the pump on the mounting plate from above so that the fastening elements on
the mounting plate engage in the recesses on the side of the pump.
7.
Push the pump downwards onto the fastening elements until they audibly engage.
8.
Attach the connecting lines (hydraulic and electric):
Ä Chapter 7.2.1 'Hydraulic installation' on page 43
Ä Chapter 7.2.2 'Electrical installation' on page 49 .
MAN046939 Rev. 6-10.2021