8.7.4
[Operating mode] [Timer]
In the [Timer] [operating mode], the runtime and standstill times of the pumps are
determined using adjustable time spans. There are two different programme types for
selection here.
In the seven-day programme, up to seven metering times can be set per weekday. Switch-
on time, metering duration and metering capacity can be individually selected for each
metering time.
With the interval programme, the pump works with a continuously repeating sequence of
set switch-on duration and interruption duration.
The following timer settings can be made:
'Seven-day programme' :
n
Ä '[Selecting/setting Operating mode] [Timer] [Seven-day programme]'
on page 86 .
With the 'Seven-day programme' , metering starts at selected metering times.
Seven metering times per weekday / metering duration and metering capacity
can be selected separately for each metering.
'Interval programme' :
n
Ä '[Selecting/setting Operating mode] [Timer] [Interval programme]' on page 88 .
In the 'Interval programme' , the pump runs and pauses for the duration of
the set switch-on and switch-off times. The process is repeated continuously,
whereby the switch-on time, switch-off time and metering capacity can be
selected.
85