Fault code - General operating faults
Display
Meaning
302: Internal fault
Operating data no
totals files
303: Internal fault
Operating data, fault
in totals files.
304: Internal fault
Start of recording
of operating
data cannot be
determined
306: Internal fault for
Dosing monitoring
dosing monitoring
(only if oval
gear meter/dosing
monitoring function
is active)
307: Internal OGM
Oval gear meter
fault - pulses
(only if oval gear
meter function is
active)
308: Internal fault
Start of recording of
alarm data cannot
be determined
309: Internal fault
Log data for start of
recording cannot be
determined
310: Internal fault
Unable to save
operating settings
312: Internal fault for
Diaphragm breakage
diaphragm breakage
(only if diaphragm
breakage function
is active and
diaphragm sensor is
connected)
313: Internal
Degassing fault (only
degassing fault
if the degassing
function is active and
a degassing valve is
connected)
Fault code 400 - motor fault
Display
Meaning
General motor fault
409: Motor control
Overheating of
has overheated
motor drive
418: No feedback
No feedback from
from motor control
gear box when
switching on
Motor fault for pulse operating mode
405: Motor control in
Dosing mode -
pressure phase
sensor not reached
407: Motor control
Suction mode -
for suction phase
sensor not reached
Motor fault for operating mode Manual, Current, Timer
Malfunctions and troubleshooting
Effect
Cause
Operating data
Error during
cannot be read
summation
Operating data
Error during
cannot be read
summation
Operating data
Error when logging
cannot be read
the start of recording
Pump keeps running
Metering capacity
or is stopped
too low or too high
(depending on
selected setting)
Pump is stopped
No pulses from oval
gear meter
Alarm data cannot
Error when logging
be read
the start of recording
Log data cannot be
Error when logging
read
the start of recording
Operating settings
Incorrect check
incorrect or
sums for parameter
incomplete
files
Pump is stopped
Diaphragm defective Replace diaphragm
Pump is stopped
Degassing valve
is not functioning
correctly
Effect
Cause
Pump is stopped
Back-pressure too
high, metering line
blocked, motor driver
defective
Pump is stopped
Contact problem
with feedback cable,
faulty feedback PCB
Pump is stopped
Back-pressure too
high, metering line
blocked
Pump is stopped
Suction pressure too
high, kink in suction
tube
159
Action
Data is reset
automatically -
no further action
required.
Check the metering
capacity
Check metering line
and oval gear meter
Data is reset
automatically -
no further action
required.
Pump is
automatically reset
to factory settings
and restarted.
Pump must be
reconfigured.
Check/replace
degassing valve
Action
Check back-
pressure, check
metering line,
replace motor PCB
Check connection
of feedback cable,
replace feedback
PCB
Check back-
pressure, check
metering line
Check suction
pressure, check
suction tube
MAN046939 Rev. 6-10.2021