Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB EcoAdd Betriebsanleitung Seite 375

Dynamische pumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pump head 120 l/h
4
2
1
A
3
Fig. 95: Replacing the diaphragm and pump head
A
Adhesive label: Tightening torque of metering head
screws
1
Metering head screws (4 pcs.)
2
Pump head
3
Suction valve
4
Pressure valve
5
Diaphragm
1.
Unscrew the suction and pressure valves (items 3 and 4).
2.
Loosen the metering head screws (item 1).
3.
Remove the pump head (item 2).
4.
Take out diaphragm (5) and intermediate plate (6).
5.
Unfasten retaining bolts for the adapter plate (7).
6.
Remove adapter plate (8a or 8b).
7.
Remove the protective diaphragm (10) from the diaphragm extension (9).
8.
Remove the diaphragm extension (9) from the plunger.
9.
Reverse this procedure for re-installation.
8
7
6
5
9
171
10 11
6
Intermediate plate.
7
Retaining bolts for the adapter plate (x4)
8a Adapter plate without sensor
8b Adapter plate with sensor
9
Diaphragm rupture drain
10 Diaphragm extension
11
Protective diaphragm
MAN046939 Rev. 6-10.2021