Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB EcoAdd Betriebsanleitung Seite 245

Dynamische pumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Tabletop mounting
1
Fig. 9: Preparations for table mounting
Only fastening elements Fig. 9 (item 2) with the number 1 are used for table
mounting.
1.
Turn the mounting plate over
2.
Insert fastening elements into the four openings marked "table" from behind and
engage into position.
3.
Turn the mounting plate over again and hold it against the required mounting
position.
4.
Use the mounting plate as a template and mark the required boreholes ( Fig. 9 , item
4) using a sharp pencil.
5.
Drill the holes.
6.
When mounting the plate on a stone surface, use suitable dowels and screws to fix
the mounting plate in place.
For table mounting, secure the mounting plate using Ø 5 mm screws.
7.
Place the pump on the mounting plate.
8.
Slide the pump backwards into the mounting plate until it engages with an audible
click.
9.
To remove the pump from the mounting plate again, push down on the
fixing tab ( Fig. 9 , item 5).
10. Attach the connecting lines (hydraulic and electric):
Ä Chapter 7.2.1 'Hydraulic installation' on page 43
Ä Chapter 7.2.2 'Electrical installation' on page 49 .
DANGER!
The mounting plate can be mounted on a suitable container. In this case,
you must not drill new holes to prevent the metering medium from offgassing.
Only containers that have been prefabricated for mounting on pumps using a
threaded insert may be used.