92
AVENTICS | Bus Coupler AES/Valve Driver AV, CANopen | R412018137–BAL–001–AE
PLC Configuration of the Valve System
M 12
M 11
M 10
8DO8M8
8DI8M8
8DI8M8
Fig. 3:
Numbering of modules in a valve system with I/O modules
M 1
AES-
D-BC-
CAN
UA
P
S1
Section 1
S2
Section 2
S3
Section 3
P
Pressure supply
The symbols for the valve zone components are explained in section 12.2 "Valve zone" on
page 107.
Example
Fig. 3 shows a valve system with the following characteristics:
Bus coupler
Section 1 (S1) with 9 valves
– Valve driver board, 4x
– Valve driver board, 2x
– Valve driver board, 3x
Section 2 (S2) with 8 valves
– Valve driver board, 4x
– Pressure regulator
– Valve driver board, 4x
Section 3 (S3) with 7 valves
– Supply board
– Valve driver board, 4x
– Valve driver board, 3x
Input module
Input module
Output module
The PLC configuration key for the entire unit is thus:
423–4M4U43
8DI8M8
8DI8M8
8DO8M8
You need this PLC configuration key to create the EDS file with the software tool "AES CANopen
EDS Creator".
M 2
M 3
M 4
P
S1
M 5
M 6
M 7
AV-EP
(M)
A
UA
S2
UA
Power supply
A
Single pressure control working connection
AV-EP Pressure regulator
M
Module
M 8
M 9
S3