TRIGger:SENT:ICONdition <Relation>
Defines how the specified identifier pattern is compared with the acquired signal. The
instrument triggers if the acquired address is equal or unequal the defined pattern.
Parameter:
<Relation>
TRIGger:SENT:IDENtifier <Pattern>
Specifies the identifier pattern to be found, in binary format. Enter the pattern in MSB
first bit order.
Parameter:
<Pattern>
TRIGger:SENT:SCONdition <Relation>
Defines how the specified status pattern is compared with the acquired signal. The
instrument triggers if the acquired address is equal or unequal the defined pattern.
Parameter:
<Relation>
TRIGger:SENT:STATus <Pattern>
Defines the status pattern as the trigger condition. Enter the words in MSB first bit
order.
Parameter:
<Pattern>
TRIGger:SENT:FCRCerror <FastCRCError>
Triggers on a detected CRC error in the transmission sequences of the fast channel.
The CRC length is 4 bits.
Parameter:
<FastCRCError>
Benutzerhandbuch 1326.1578.03 ─ 19
UNUSed | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
*RST:
EQUal
String with max. 7 characters. Characters 0, 1, and X are allo-
wed. If you define a pattern shorter than the pattern length, the
missing LSB are filled with X.
UNUSed | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
*RST:
EQUal
ON | OFF
*RST:
ON